C500X Expansion Joint

Technical Information

For further information relating to the installation and Health & Safety please click here to view installation instructions.

 

     

PFC Corofil C500X is a compressible product to fill fire rated joints in compartment floors and walls. Tested to BS476 Part 20, Corofil C500X provides up to 4 hours' fire protection.

  • Up to 4 hours' fire protection.
  • Simple to install
  • Water resistant
  • Maintenance free
PFC Corofil C500X Compressed into blockwork joints PFC Corofil C500X firestopping vertical expansion joint

Description

Corofil C500X Intumescent Expansion Joint is a highly compressible strip formed by laminating fire retardant foam to a graphite based intumescent polymer.

Corofil C500X Intumescent Expansion Joint is delivered to site in pre-formed sections. The section size depends on the joint size and the fire rating that needs to be achieved (See Fire Rating).

Corofil C500X Intumescent Expansion Joint is simply compressed by hand and is then pushed into the gap. Adjacent pieces of the product are simply butted together. There is no need to use any adhesives or intumescent sealant in conjunction with the product.

In a fire, the graphite based intumescent material swells to form a hard char which prevents the passage of fire and smoke through the joint.

Corofil C500X Intumescent Expansion Joint is suitable for use in:

  • Blockwork cavities
  • Expansion joints
  • Structural joints
  • Curtain wall/Concrete slab interfaces

Fire Rating

Joint Size Integrity Insulation Size of Product Product Code
1 - 10mm 240 mins 235 mins 14 x12mm C500X1
11 -25mm 120 mins 16 mins 29 x 12mm C500X2
11 -25mm 240 mins 145 mins 29 x 25mm C500X3
26 - 50mm 120 mins 23 mins 56 x 25mm C500X4

C144 Cavity Firestop Strips and Firestop Blocks being a component of structure satisfies both integrity and insulation requirements as shown in the table opposite.

Building Regulations 2000 - Approved Document B - B2/3/4 – Internal fire spread (structure), paragraphs 0.10 – 0.11, state that the spread of fire inside a building can be restricted, by provisions for elements of structure to have a specified minimum period of fire resistance. Fire resistance is defined in terms of both integrity and insulation requirements when applied to fire separating elements.

Acoustic Rating

Please consult our sales office with details of:

  • Wall/floor construction
  • Acoustic rating required

Specification

Install PFC Corofil C500X Intumescent Expansion Joint to provide up to 4 hours' fire rating. Installation to be fully in accordance with manufacturer’s instructions.

To Order

Contact our technical sales office (Tel: 020 8391 0533) with the following details:

  • Fire Rating
  • Joint Size
  • Quantity (lin m)